1 Air Flow Regimes in an Air Conditioned Playground Zone of Open-Roof Football Stadium (LB-17-C007)

Essam E. Khalil, Cairo University Faculty of Engineering
Esmail ElBialy, Dr.Ing., Cairo University Faculty of Engineering
Waleed AbdelMaksoud, Ph.D., P.E., Cairo University Faculty of Engineering
Mohamed E. Ashmawy, P.E., Cairo University Faculty of Engineering
This paper examines developing air conditioning systems in the playground zone of a stadium by employing several kinds of technologies to cool the outdoor spaces. The most serious challenge of air conditioning in a playground zone in stadium is controlling the temperature and humidity in the outdoor area and also the enormous energy needed by the cooling system to maintain thermal comfort conditions within the football playground area. The main task for the analyzed model was to ensure the better method to distribute air to achieve the human comfort level for players and reducing the cooling capacity of playground zone by using a large sunshade to reduce the sun's rays and maintain the stadium's temperature.